UCERB 24 | CyberResearch® Digital I/O |
Power
Table
Parameter | Conditions | Specification |
|
|
|
USB +5 V input voltage range |
| 4.75 V min. to |
|
| 5.25 V max. |
USB +5 V supply current | All modes of operation | 10 mA max |
External power supply (required) |
| 9 V ±10% @ 3 A |
Voltage supervisor limits - PWR | Vext < 6.0 V, Vext > 12.5 V | PWR LED = Off |
LED |
| (power fault) |
| 6.0 V < Vext < 12.5 V | PWR LED = On |
External power consumption | All relays on, 100 mA downstream hub | 1.5 A typ, 1.8 A max |
| power |
|
| All relays off, 100 mA downstream hub | 230 mA typ, 270 mA max |
| power |
|
External power input
Table
Parameter | Conditions | Specification |
|
|
|
External power input |
| +6.0 VDC to 12.5 VDC (9 VDC power supply |
|
| included). |
Voltage supervisor limits - PWR LED | 6.0 V > Vext or Vext > | PWR LED = Off (power fault) |
(Note 1) | 12.5 V |
|
| 6.0 V < Vext < 12.5 V | PWR LED = On |
External power adapter (included) |
| +9 V ±10%, @ 3 A |
|
|
|
Note 1: The UCERB 24 monitors the external +9 V power supply voltage with a voltage supervisory circuit. If this power supply exceeds its specified limit, the PWR LED will turn off indicating a power fault condition.
External power output
Table
Parameter | Conditions | Specification | |
|
|
|
|
External power output - current |
| 4.0 | A max. |
range |
|
|
|
External power output (Note 2) | Voltage drop between power input and daisy chain power | 0.5 | V max |
| output |
|
|
Compatible cable(s) for daisy | x = 2 , 3 or 6 | ||
chain |
| feet |
|
Note 2: The daisy chain power output option allows multiple boards to be powered from a single external power source in a daisy chain fashion. The voltage drop between the module power supply input and the daisy chain output is 0.5 V max. Users must plan for this drop to ensure the last module in the chain will receive at least 6.0 VDC.
20 | ©Copyright 2005 CyberResearch, Inc. |