CY7B9910

CY7B9920

 

 

 

 

CY7B9910–5

 

CY7B9920–5

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Description

Min

 

Typ

Max

Min

 

Typ

Max

Unit

 

 

 

 

 

 

 

 

 

 

 

 

f

Operating Clock

FS = LOW[1, 2]

15

 

 

30

15

 

 

30

MHz

NOM

Frequency in MHz

 

 

 

 

 

 

 

 

 

 

 

FS = MID[1, 2]

25

 

 

50

25

 

 

50

 

 

 

FS = HIGH[1, 2, 3]

40

 

 

80

40

 

 

80[12]

 

tRPWH

REF Pulse Width HIGH

 

5.0

 

 

 

5.0

 

 

 

ns

tRPWL

REF Pulse Width LOW

 

5.0

 

 

 

5.0

 

 

 

ns

tSKEW

Zero Output Skew (All Outputs)[13, 14]

 

 

0.25

0.5

 

 

0.25

0.5

ns

tDEV

Device-to-Device Skew[8, 15]

 

 

 

 

1.0

 

 

 

1.0

ns

tPD

Propagation Delay, REF Rise to FB Rise

–0.5

 

0.0

+0.5

–0.5

 

0.0

+0.5

ns

t

Output Duty Cycle Variation[16]

–1.0

 

0.0

+1.0

–1.0

 

0.0

+1.0

ns

ODCV

 

 

 

 

 

 

 

 

 

 

 

t

Output Rise Time[17, 18

 

0.15

 

1.0

1.5

0.5

 

2.0

3.0

ns

ORISE

 

 

 

 

 

 

 

 

 

 

 

t

Output Fall Time[17, 18]

 

0.15

 

1.0

1.5

0.5

 

2.0

3.0

ns

OFALL

 

 

 

 

 

 

 

 

 

 

 

tLOCK

PLL Lock Time[19]

 

 

 

 

0.5

 

 

 

0.5

ms

tJR

Cycle-to-Cycle Output Jitter

Peak to Peak[8]

 

 

 

200

 

 

 

200

ps

 

 

RMS[8]

 

 

 

25

 

 

 

25

ps

Notes

8.Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect these parameters.

9.CMOS output buffer current and power dissipation specified at 50 MHz reference frequency.

10.Applies to REF and FB inputs only.

11.Test measurement levels for the CY7B9910 are TTL levels (1.5V to 1.5V). Test measurement levels for the CY7B9920 are CMOS levels (VCC/2 to VCC/2). Test conditions assume signal transition times of 2ns or less and output loading as shown in the AC Test Loads and Waveforms unless otherwise specified.

12.Except as noted, all CY7B9920–2 and –5 timing parameters are specified to 80 MHz with a 30 pF load.

13.tSKEW is defined as the time between the earliest and the latest output transition among all outputs when all are loaded with 50 pF and terminated with 50Ω to 2.06V (CY7B9910) or VCC/2 (CY7B9920).

14.tSKEW is defined as the skew between outputs.

15.tDEV is the output-to-output skew between any two outputs on separate devices operating under the same conditions (VCC, ambient temperature, air flow, and so on).

16.tODCV is the deviation of the output from a 50% duty cycle.

17.Specified with outputs loaded with 30 pF for the CY7B99X0–2 and –5 devices and 50 pF for the CY7B99X0–7 devices. Devices are terminated through 50Ω to 2.06V (CY7B9910) or VCC/2 (CY7B9920).

18.tORISE and tOFALL measured between 0.8V and 2.0V for the CY7B9910 or 0.8VCC and 0.2VCC for the CY7B9920.

19.tLOCK is the time that is required before synchronization is achieved. This specification is valid only after VCC is stable and within normal operating limits. This parameter is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits.

Document Number: 38-07135 Rev. *B

Page 6 of 11

[+] Feedback

Page 6
Image 6
Cypress CY7B9910, CY7B9920 Operating Clock FS = LOW 1 MHz, Frequency in MHz FS = MID 1 FS = High 1, 2, Output Rise Time 17