CY7C1460AV25
CY7C1462AV25
CY7C1464AV25
Document #: 38-05354 Rev. *D Page 13 of 27
2.5V TAP AC Test Conditions
Input pulse levels ............................................... VSS to 2.5V
Input rise and fall time ....................................................1 ns
Input timing reference levels.........................................1.25V
Output reference levels.................................................1.25V
Test load termination supply voltage.............................1.25V
2.5V TAP AC Output Load Equivalent1.8V TAP AC Test Conditions
Input pulse levels.....................................0.2V to VDDQ – 0.2
Input rise and fall time.....................................................1 ns
Input timing reference levels...........................................0.9V
Output reference levels..................................................0.9V
Test load termination supply voltage..............................0.9V
1.8V TAP AC Output Load Equivalent

T

DO

1.25V

20p

F

Z = 50

O

50

T

DO

0.9V

20p

F

Z = 50

O

50

TAP DC Electrical Characteristics And Operating Conditions
(0°C < TA < +70°C; VDD = 2.5V ±0.125V unless otherwise noted)[11]
Parameter Description Test Conditions Min. Max. Unit
VOH1 Output HIGH Voltage IOH = –1.0 mA VDDQ = 2.5V 1.7 V
VOH2 Output HIGH Voltage IOH = –100 µAV
DDQ = 2.5V 2.1 V
VDDQ = 1.8V 1.6 V
VOL1 Output LOW Voltage IOL = 1.0 mA VDDQ = 2.5V 0.4 V
VOL2 Output LOW Voltage IOL = 100 µAV
DDQ = 2.5V 0.2 V
VDDQ = 1.8V 0.2 V
VIH Input HIGH Voltage VDDQ = 2.5V 1.7 VDD + 0.3 V
VDDQ = 1.8V 1.26 VDD + 0.3 V
VIL Input LOW Voltage VDDQ = 2.5V –0.3 0.7 V
VDDQ = 1.8V –0.3 0.36 V
IXInput Load Current GND VI VDDQ –5 5 µA
Identification Register Definitions
Instruction Field CY7C1460AV25
(1M ×36) CY7C1462AV25
(2M ×18) CY7C1464AV25
(512K ×72) Description
Revision Number (31:29) 000 000 000 Describes the version number
Device Depth (28:24) 01011 01011 01011 Reserved for Internal Use
Architecture/Memory Type(23:18) 001000 001000 001000 Defines memory type and archi-
tecture
Bus Width/Density(17:12) 100111 010111 110111 Defines width and density
Cypress JEDEC ID Code (11:1) 00000110100 00000110100 00000110100 Allows unique identification of
SRAM vendor
ID Register Presence Indicator (0) 1 1 1 Indicates the presence of an ID
register
Note:
11.All voltages referenced to VSS (GND).
[+] Feedback