Electrical Connection

Installation Specifications

Junction Box Location warning

Do not install the dishwasher unless the electrical service provided meets the dishwasher specifications (see page 5).

A qualified technician must complete the installation of this built-in appliance. The owner is responsible to make sure the dishwasher is properly installed. Improper connection of the electrical wiring may create an electric shock or fire hazard and may result in damage to the dishwasher’s electrical system.

To avoid an electrical shock hazard, turn off power to the electrical outlet or junction box at the circuit breaker panel or fuse box before proceeding. Do not turn on the power or water supply until instructed to do so on the following pages.

Do not allow any material, including the hoses or electrical wiring to be directly behind the dishwasher while pushing it into the cut-out opening. Carefully pull the slack out of both hoses and the wiring from outside the cut-out during push back to prevent pinching. An electric shock hazard or water damage may result from pinched wires or hoses. Damage due to improper installation is not covered under warranty.

Electrical Connection

1.Make sure power to the electrical receptacle or junction box is off.

2.Before connecting the wiring and the plumbing, push the dishwasher into position with the back of the unit about six (6) inches in front of the cut-out.

3.Remove the two (2) screws that hold the toe kick assembly in place and remove it. NOTE: Do not reinstall the toe kick until the dishwasher is completely installed and tested.

Door

 

Retaining screw,

Toe kick

assembly

2 places

 

4.Remove the dishwasher junction box cover screw. The junction box is mounted to the dishwasher chassis below the door.

Junction Box Wiring Screw

Junction Box Location

5.Remove the junction box cover.

6.Install a 3/4” UL/CSA approved strain relief on the base of the dishwasher junction box.

Strain

Wire

nuts

relief

 

Base

Manual background Ground connection

Junction Box Wiring

7.Strip the three (3) wires on the end of the electric cord or one end of the wire that will connect to the house wiring.

8.Feed the end of the wire or cord through the dishwasher chassis into the junction box base through the strain relief.

9.Loosen the grounding screw on the base and connect the green wire. Tighten it into place.

10.Connect the power cord (or house wiring) black and white wires to the black and white wires inside the junction box. Match the colors. Use wire nuts to connect them.

11.Tighten the strain relief. Pull gently on the wiring from the back to make sure it is secure.

12.Replace the junction box cover and screw.