Preparing for Installation
warning
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
Preparing the Location
Carefully check the location where the dishwasher is to be installed. Put it in a location with convenient access. Make certain that electrical power can be provided in the selected location.
Plan the installation so that the appliance can be removed if service is required.
IMPORTANT: Follow all cabinet and countertop minimum dimensions shown below to insure safe operation.
Prepare the installation location as shown below. All minimum product dimensions be must met or exceeded (see page 3). Dimensions shown provide minimum clearances, unless otherwise noted.
The floor must be level and all
Fasten | |
under counter top and adjacent cablinets | |
90° | 90° |
| 33 3/4” |
| (85.7 cm) |
| to |
| 36 1/4” |
| (92.1 cm) |
24” (61.0 cm) | Access Hole for Utilities |
| 8” H X 5“ D |
| (20.3 cm X 12.7 cm) |
| 24” (61.0 cm) |
CUT-OUT FRONT VIEW
Min. Countertop 25" (63.5 cm)
CABINET INSTALLATION SIDE VIEW