Water Filter Performance Data

System tested and certified by NSF International against NSF/ANSI Std 42 for the reduction of Chlorine Taste and Odor, Particulate Class I and against NSF/ANSI 53 for the reduction of Cysts, Turbidity, Asbestos, Mercury, Lead, Benzene, p-Diclorobenzene, Carbofuran

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

Chlorine Taste/Odor

50% reduction

1.88 mg/L

2.0 mg/L ± 10% At least

0.06 mg/L

0.05 mg/L

 

96.84

>97.26

Particulate Class I*

85% reduction

5,700,000 #/mL

10,000 particles/mL

69,000 #/mL**

30,583 #/mL

 

98.94

99.52

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

Lead: @ pH 6.5

0.010 mg/L

0.153 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

 

>99.29%

>99.35%

Lead: @ pH 8.5

0.010 mg/L

0.150 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

 

>99.29%

>99.33%

Mercury: @ pH 6.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

 

90.91

95.70

Mercury: @ pH 8.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0015 mg/L

0.0008 mg/L

 

75.93

86.22

 

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 mg/L

0.15 ± 10%

< 0.001mg/L

< 0.001mg/L

 

91.67%

92.97%

 

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002mg/L

< 0.002mg/L

 

75.31%

76.99%

 

 

 

 

 

 

 

 

 

Asbestos

99%

155 MF/L

107 to 108 fibers/L††

< 1 MF/L

< 1 MF/L

 

>99.99%

>99.99%

Live Cysts‡

>99.95%

166,500 #/L

50,000/L min.

< 1 #/L

< 1 #/L

 

>99.99%

>99.99

Turbidity

0.5 NTU

10.7 NTU

11 ± 1 NTU

0.49 NTU

0.31 NTU

 

95.2

>97.09%

 

 

 

 

 

 

 

 

 

Lindane

0.0002 mg/L

0.0002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000mg/L

 

96.50%

>98.72%

 

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

 

 

*

Class I particle size: >0.5 to <1 um

 

 

 

 

 

 

 

**

Test requirement is at least 100,000 particles/mL of AC Fine Test Dust

 

 

 

 

 

 

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions

 

 

 

 

††

Fibers greater than 10 um in length

 

 

 

 

 

 

 

Based on the use of Cryptosporidium parvum oocysts

 

 

 

 

 

 

Specifications

Water Supply:

City or well

Service Flow Rate:

.78 gpm (2.9 L/min) @ 60 psi

Water Pressure:

35 - 120 psi (241 - 827 kPa)

Water Temperature:

33° - 100°F (1° - 38°C)

It is essential that operational, maintenance and filter replacement requirements be carried out for the product to perform as adver- tised.

The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. For models without filter status lights, replace the filter every 6 months. Use Dacor replacement cartridge AFF3.

This product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed above. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.