Installation Instructions

Connecting Conduit to the Range

NOTE: See page 14 for instructions to connect an appliance cord to the range.

1.Remove the range electrical access cover from the back of the range.

2.If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link.

3.Remove the nut from the conduit strain relief (not included).

4.Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box.

5.Before connecting the wires, slide the strain relief nut over the wires and thread it onto the conduit strain relief inside the box. Tighten into place.

6.Connect the white wire to the neutral terminal inside the box.

7.Connect the black wire to the L1 power supply terminal.

8.Connect the red wire to the L2 power supply terminal.

9.If using a 4-wire connection, connect the green wire to the grounding screw inside the box.

Bare wire

connections

Loop and spade terminal

connections

10. Replace the range electrical access cover.

L1 terminal

Neutral terminal

Jumper link

L2 terminal

Back wire

White wire

Red wire

Conduit strain relief nut

3-Wire Conduit Connection -

Where Local Codes Permit

L1 terminal

Neutral terminal

L2 terminal

Link removed Grounding screw

Red wire

Green wire

White wire

Back wire

Conduit strain relief nut

4-Wire Conduit Connection

11