Installation Instructions

Electrical Connection (cont.)

Appliance Cord Connections - Where Local Code Permits

warning

Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.

1.Remove the range electrical access cover from the back of the range.

2.If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link.

3.Remove the conduit bracket from the bottom of the range electrical box.

Remove link on

4-wire installations

Remove conduit

bracket before strain

relief installation

4.Disassemble and remove the strain relief from the appliance cord (not included). Insert the tabs on the two parts of

the strain relief into the hole on the bottom of the box and reassemble it so that the tabs are below the box and the strain relief itself is inside the box.

Strain relief

5.Slide the end of the appliance cord into the strain relief from the bottom of the box. See facing page.

6.Connect the white (neutral) wire to the neutral terminal in the box.

7.Connect the L1 wire to the L1 power supply terminal inside the box.

8.Connect the L2 wire to the L2 power supply terminal inside the box.

9.If using a 4-wire connection, connect the ground wire to the grounding screw inside the box using a loop or spade terminal.

Bare wire

connections

Loop and spade terminal

connections

10.Tighten the strain relief so that the appliance cord is held snuggly in place.

11.Replace the range electrical access cover.

12.With power turned off at the circuit breaker panel or fuse box, connect the plug on the end of the appliance cord to the power receptacle.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of range

 

Reassemble with tabs

electrical box

 

below and clamp above

 

14