ELECTRICAL ADJUSTMENT

(3) SYNC TIP FREQUENCY

Adjustment Parts

Check Point

Measuring Equipment

Test Tape

Input Signal

R391

TJ391

Frequency Counter

-

-

 

 

 

 

 

vCONNECTION METHOD

R391

TJ391

 

 

SYNC TIP

CH-1

 

Oscilloscope

 

 

 

 

CH-2

VIDEO IN is shorted with Ground

vADJUSTMENT PROCEDURE

1)Set the VCR to STOP mode without Video Signal.(VIDEO IN JACK is shorted with Ground)

2)Connect the frequency counter TJ391.

3)After Inserting Rec Tape REC in SP Mode

4)Adjust R391 to obtain 4.20 ± 0.1 MHz.