CIRCUIT OPERATION
TAPE END OUT
When the recording tape ends during recording, end sensor will be detected. This port is used Alarm to outsider until release the end sensor detecting.
5V
0V
END Detect |
HIGH |
END Detect |
LOW |
SW OUTPUT
This port is used triggering video signal with external equipment during recording.
VIDEO SIGNAL
SW
OUT 1FIELD
16.67ms |
SW
OUT 2FIELD
4ms
SERIES OUTPUT
When the series recording proceeds after setting the series recording to “on”, this port is used to output the control signal to the set which will be recorded continuously after
5V
0V
250ms |