TROUBLESHOOTING FLOW CHART

F.

Drum M/T and capstan M/T

rotate at regular speed.

(IN REC MODE)

Is C. sync applied to

NO

 

pin 93 of IC501?

 

 

 

 

 

YES

 

 

 

 

 

 

Check motor

 

 

 

 

G.

Emergency mode when plugging (power cord)

NO

Is ever 5V applied?

YES

Does X501 crystal

NO

 

oscillate?

 

 

 

 

 

YES

 

 

 

NO

 

 

 

 

Is CAM SW DATA correct?

YES

Check IC501.

Check C. sync of video

IC and pattern.

Check power Module.

Check IC501 and X501.

Recheck connector and

CAM SW contact.

31

Page 32
Image 32
Daewoo DV-K580NZ-T service manual REC Mode