Daewoo KOR-63DB0S plied to RELAY RY2 coil, blow, Open power sup, power supply cord, switch

Models: KOR-63DB0S KOR-63DB9S KOR-63FB9S KOR-63FB0S

1 34
Download 34 pages 52.26 Kb
Page 19
Image 19
blow.

CONDITION

CHECK

RESULT

CAUSE

REMEDY

Outlet has

Check continuity of magnetron

No

Defective mag-

Replace

 

proper volt-

Continuity

netron

 

 

 

age Fuse

 

 

 

 

does not

 

No

Defective mag-

Replace

blow.

Check continuity of

 

 

noise filter board

Continuity

netron

 

 

Check continuity of

No

Open power sup-

Replace

 

 

 

power supply cord

Continuity

ply cord

 

 

 

Normal

Defective touch

Replace

 

 

 

 

 

 

 

control circuit

 

NOTE

All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.

(TROUBLE 2) Display shows all figures selected, but oven does not start cooking, even though desired program and time are set and start button is tapped.

CONDITION

Turn table motor and oven lamp do not turn on

CHECK

Check continuity of primary inter-

lock switch

Check continuity of secondary

interlock switch

Check D.C. voltage being sup-

plied to RELAY (RY2) coil

RESULT

 

 

CAUSE

 

 

REMEDY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

Malfunction of pri-

 

 

Adjust or

Continuity

 

 

mary interlock

 

 

replace

 

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

Malfunction of sec-

 

 

Adjust or

Continuity

 

 

 

 

replace

 

 

ondary interlock

 

 

 

 

 

 

 

 

 

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 V

 

Defective touch

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx.

 

 

Faulty contacts of

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

12 VDC

 

RELAY (RY2) or

 

 

 

 

 

 

open relay coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

Page 19
Image 19
Daewoo KOR-63DB0S, KOR-63FB0S plied to RELAY RY2 coil, blow, Open power sup, power supply cord, switch, Malfunction of sec