Daewoo KOR-63DB9S Printed Circuit Board, Circuit Check Procedure, Low Voltage Transformer check

Models: KOR-63DB0S KOR-63DB9S KOR-63FB9S KOR-63FB0S

1 34
Download 34 pages 52.26 Kb
Page 26
Image 26
PRINTED CIRCUIT BOARD

PRINTED CIRCUIT BOARD

1. CIRCUIT CHECK PROCEDURE

1. Low Voltage Transformer check

The low voltage transformer is located on the P.C.B.

Measuring condition: input voltage : 230V/Frequency : 50Hz

Terminal Voltage

LOAD

NO LOAD

 

 

 

4-8

AC 25.8 V

AC 31.8 V

NOTE :

1.Refer to Circuit Diagram (point 4).

2.Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.

3.The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.

2.Voltage check

• Key check point

NO

CHECK POINT

REMARK

1

IC 1 PIN 14

-5 VDC

 

 

 

2

IC 1 PIN 22

 

T:20ms(50Hz)

3

IC 1 PIN 1 OR 2

T:250ns(4MHz)

• Check method

NO

MEASURE POINT
WAVE FORM
REMEDY

REMARK

 

 

 

 

 

1

MP1

DC -5V±0.25V

Replace VL1, EC1

NO LOAD

 

 

 

 

 

2

MP2

DC -12V±2.0V

Replace EC2, D9, 10, 11

NO LOAD

 

 

 

 

 

NOTE :

Each measure point must be measured with GND points.