Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Component

Test Procedure

Results

Electronic

F11 –Upper Oven >650°F with door unlocked

Check actual upper oven temperature,

range control

F12 –Lower Oven >650°F with door unlocked

if > 650°F check sensor.

 

Check actual lower oven temperature,

 

F13 –Upper Oven >950°F with door locked

if > 650°F check sensor.

 

Check actual upper oven temperature,

 

F14 –Lower Oven >950°F with door locked

if > 950°F check sensor.

 

Check actual lower oven temperature,

 

F17 –Membrane switch is not responding

if > 950°F check sensor.

 

Check membrane switch for connection or damage.

 

F31 –Upper sensor is shorted at (< 100 ) or

 

 

open at (>5 K )

Check upper sensor, harness, and connections

 

F32 –Lower sensor is shorted at (< 100 ) or

Check upper sensor, harness, and connections

 

open at (>5 K )

 

 

 

Engineering

Press BAKE pad.

Used to view the actual oven temperature for both ovens at all

Test Mode

Enter 100°F using the number pads.

times, even when an oven function is active.

 

Immediately push and hold BAKE pad for appropriate oven

This mode will also display the current fault code for 5

 

approximately 3 seconds.

seconds in the time digits.

 

This mode can also be entered by pressing the hidden pad

 

 

for 3 second located to the left of the lower oven light pad.

 

Fault codes

F00 –No fault

Default from factory

accessed

F15 –Upper hardware failure within control

Replace control

through

F16 –Lower hardware failure within control

Replace control

Engineering

F18 –Shorted key in membrane switch

Check membrane connection

Test Mode

F19 –Internal communication errors within control

Replace control

 

 

F1A –Upper latch switches

Check latch wire harness

 

F1B –Lower latch switches

Check latch wire harness

 

F1C –Upper door switch

Check lock wire harness

 

F1D –Lower door switch

Check lock wire harness

 

F1E –Sensor input not calibrated

Verify sensor is operating properly

 

F1H –EEPROM error

Replace control

 

F1L –Temp in ovens are the same for long period

Verify sensor is operating properly

 

F1N –Internal voltage on control not working

Replace control

 

F91 –Upper lock switch is not correct

Check lock wire harness, and lock switch

 

Check lock wire harness, and lock switch

 

F92 –Upper unlock switch is not correct

 

Check lock wire harness, and lock switch

 

F93 –Control does not see upper door lock

 

Check lock wire harness, and lock switch

 

F94 –Lower lock switch is not correct

 

Check lock wire harness, and lock switch

 

F95 –Lower unlock switch is not correct

 

Check lock wire harness, and lock switch

 

F96 – Control does not see lower door lock

 

Disconnect power for 60 seconds. If EE reappears, replace ERC

 

EE –Control cannot read E-PROM. Unit will shut down.

 

Test Mode

This mode must be activated within the first 5 minutes of

Upper Bake: Energizes upper bake element

 

power up.

Lower Bake: Energizes lower bake element

 

Press BROIL and CANCEL pad for approximately 3 seconds.

Upper Broil: Energizes upper broil element

 

If oven temperature is greater than 400°F, the Test Mode

Convection Bake: Energizes convection fan

 

Upper Oven Light: Energizes upper oven light

 

cannot be activated or will abort if active.

Lower Oven Light: Energizes lower oven light

 

Press and hold individual pads for 4 seconds to activate.

Upper Clean: Energizes upper motorized door lock

 

Lower Clean: Energizes lower motorized door lock

 

Display will have dashes in all segments to indicate the mode is

Stop Time: Energizes Beeper

 

Cook Time: Displays error codes

 

active.

Timer 1: Energizes ROM version

 

 

Timer 2: Energizes EEPROM version

 

 

Keep Warm: Cooling Fan

 

 

Clock: All display segments light

 

 

If functions do not perform as specified, replace ERC

Oven

Push BAKE pad.

While increasing or decreasing oven temperature, this does not

temperature

Enter 550°F using the number pads.

affect self-cleaning temperature.

adjustment

Immediately push and hold BAKE pad for appropriate oven

Holds offset through power outage.

 

approximately 3 seconds.

 

To decrease or increase oven temperature. Push AUTO SET

 

 

pad until negative or positive numbers appear. Oven can be

 

 

adjusted from -35° to +35° (-37.2° to + 1.6° C) in 5° F (2.7° C).

 

 

To avoid over adjusting oven move temperature -5° each time.

 

 

Push OVEN CANCEL button.

 

20

16023417

©2004 Maytag Services

Page 20
Image 20
Jenn-Air JDR8895ACS/W, JDR8895AAB/S/W manual This mode will also display the current fault code for

JDR8895AAB/S/W, JDR8895ACS/W specifications

The Jenn-Air JDR8895ACS/W and JDR8895AAB/S/W are two premium model double oven ranges that exemplify luxury kitchen appliances. These models are designed for those who appreciate culinary craftsmanship, combining elegance with cutting-edge technology. Both offerings provide spacious interiors, allowing chefs to prepare multiple dishes simultaneously, a crucial feature for anyone who enjoys entertaining.

One of the standout features of the Jenn-Air JDR8895 series is its impressive dual-fuel capability, providing the precision of gas cooking with the consistent results of an electric oven. The gas burners offer a variety of power levels, accommodating different cooking techniques, from searing meats to simmering delicate sauces. The oven uses an electric convection system that circulates hot air, ensuring even baking results, which is particularly beneficial for baking pastries or casseroles.

Another defining characteristic is the sleek and modern design, which features a stainless steel exterior that not only enhances the kitchen's aesthetic but also promotes durability and easy cleaning. The intuitive control panel offers smooth, touch-sensitive controls for various settings, making it user-friendly even for novice cooks.

Among the technologies incorporated in the Jenn-Air JDR8895 models is the advanced temperature probe, which allows for precise monitoring of internal temperatures without opening the oven door. This feature is invaluable for achieving perfectly cooked meats and maintaining optimal oven conditions.

In addition to performance features, these ranges are equipped with a self-cleaning mode that simplifies maintenance, allowing users to spend more time cooking rather than cleaning. The built-in Wi-Fi connectivity enables remote monitoring and control of the range through a compatible smartphone app, offering convenience for the modern home chef.

In terms of safety, these models are designed with features such as automatic shut-off and child lock options, providing peace of mind in busy kitchens.

Overall, the Jenn-Air JDR8895ACS/W and JDR8895AAB/S/W range models embody sophistication, functionality, and technology, appealing to anyone looking to elevate their culinary experience. These dual-fuel ranges not only meet high-performance standards but also introduce smart cooking solutions that make every meal an occasion to remember.