Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.
Component Testing
Illustration | Component | Test Procedure | Results | ||
|
|
| Oven light socket | Remove one wire from receptacle |
|
|
|
|
| and test resistance of terminals | Indicates continuity with bulb screwed in. |
|
|
|
| Measure voltage at oven light | 120 VAC, see wiring diagram for terminal |
|
|
|
|
| identification. |
|
|
|
|
| If no voltage is present at oven light, check |
|
|
|
|
| wiring or light switches. |
|
|
| Autolatch assembly | Disconnect wires and test for | See wiring diagram for schematic layout. |
|
|
| with switch | continuity per wiring diagram. | Access assembly by removing left side |
|
|
|
|
| panel. |
|
|
|
| Refer to Parts Manual for correct |
|
|
|
|
| autolatch switch associated with the |
|
|
|
|
| correct manufacturing number. |
|
5 K btu |
|
| 270° valve | Verify gas is supplied. |
|
9.2 K btu (2) |
|
|
| ||
16 K btu |
|
|
| Adjust set screw for simmer control. |
|
12 K btu |
|
|
|
|
|
|
|
| Spark 270° switch | Test for voltage at terminals | 120 VAC |
|
|
|
| Disconnect wiring and check for |
|
|
|
|
| continuity in LITE position | Continuity in LITE position. |
|
|
| Spark ignition | Test for resistance of spark lead | Continuity |
|
|
| electrode |
|
|
|
|
|
| Test ignitor to chassis | No continuity from ignitor to chassis. |
5 K btu |
|
| Top surface burner | Verify gas is supplied | Check for obstructions in burner ports. |
9.2 K btu (2) |
|
|
| ||
16 K btu |
|
|
| Verify burner cap is positioned |
|
12 K btu |
|
|
| correctly. |
|
L | A | B | Spark module 4 + 0 | Test for voltage at terminals L and N | 120 VAC |
N |
| A1 B1 |
| Check polarity and ground | See wiring diagram |
|
|
|
| ||
|
|
| Temperature sensor | Measure resistances | Approximately 1100 Ω at room temperature |
|
|
|
|
| 75°F. |
|
|
| Pressure regulator | Verify gas pressure (W.C.P.). | 5" Natural |
|
|
|
| If on LP service verify proper gas | 10" LP/propane |
|
|
|
|
| |
|
|
|
| supply conversion. |
|
|
|
| Door plunger switch | Remove switch from unit and |
|
|
|
|
| measure the following points: |
|
|
|
|
| C NO | Plunger in infinite, Plunger out continuity. |
|
|
| Bake element, Upper | Disconnect wire leads to element |
|
|
|
|
| and measure resistance of terminals | Approximately 31.0 Ω, if not replace. |
|
|
|
| Measure voltage at bake element | 240 VAC, see wiring diagram for terminal |
|
|
|
|
| identification. If no voltage is present at |
|
|
|
|
| bake element check wiring. |
|
|
| Bake element, Lower | Disconnect wire leads to element |
|
|
|
|
| and measure resistance of terminals | Approximately 21.3 Ω, if not replace. |
|
|
|
| Measure voltage at bake element | 240 VAC, see wiring diagram for terminal |
|
|
|
|
| identification. If no voltage is present at |
|
|
|
|
| bake element check wiring. |
|
|
| Broil element, Upper | Disconnect wire leads to element |
|
|
|
|
| and measure resistance of terminals | Approximately 25.4 Ω, if not replace. |
|
|
|
| Measure voltage at broil element | 240 VAC, see wiring diagram for terminal |
|
|
|
|
| identification. If no voltage is present at |
|
|
|
|
| broil element check wiring. |
16 | 16023417 | ©2004 Maytag Services |