Additional Procedures | Battery Verification - 3 | |
|
|
|
Negative Probe
Positive
Probe
Caution: Review the ESD precautions in Bulletins/ Safety.
1Set the voltmeter to the 10 volts DC scale.
2Hold the positive probe of the voltmeter to the positive end of the battery and the negative probe to the negative end of the battery.
3If the battery voltage is below 3.0 volts, replace the battery. Refer to “Battery Replacement” in this chapter.