Jenn-Air JDR8895AAB/S/W manual “Quick Test” Mode for Electronic Range Control, Testing Procedures

Models: JDR8895AAB/S/W JDR8895ACS/W

1 68
Download 68 pages 3.69 Kb
Page 19
Image 19
“Quick Test” Mode for Electronic Range Control

Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

“Quick Test” Mode for Electronic Range Control

Follow the procedure below to perform the Electronic Range Control (ERC) quick test. Instructions must be entered within 32 seconds of each other (via the touch pad) or the ERC will exit the quick test.

1.Press and hold the UPPER CANCEL and BROIL pads for 3 seconds.

2.Once the control has entered the “Quick Test” mode, release both pads.

3.Press each of the following pads indicated in the table below.

NOTE: Press the applicable pad once to activate the associated response.

Press the applicable pad a second time to deactivate the associated response.

Display indicates the following:

Pad

Response

 

BAKE

Bake DLB and Bake relay activated

BROIL

Broil DLB and Broil relay activated

KEEP WARM

Bake DLB and Broil DLB activated

CONVECT BAKE

Convection Fan on low speed

CONVECT ROAST

Convection Fan on high speed

CLEAN

MDL relay activated

COOK & HOLD

Displays last diagnostic code

FAVORITE

Displays EEPROM version number

TIMER

Displays main code version number

CLOCK

All display segments illuminated

OVEN LIGHT

Oven light activated

CANCEL

Exit Quick Test mode

1

Even segments on

2

Odd segments on

3

Convection Ring activated; Convection Ring DLB activated

4

N/A

5

N/A

6

N/A

7

N/A

8

N/A

9

N/A

AUTOSET

Steps through last 5 diagnostic codes

Setup Options (0) pad is pressed “Press Desired Pad for Selection” will scroll in the display. When a feature is displayed the AUTO SET pad is used to toggle the options. Use the chart below to identify the available options.

Control

Pad

Default Option
Function

Selection

 

12 hour shut-off

1

12 HR Energy Saver ON

Timer beeps

2

Timer Reminder Beeps for 5 Min.

 

 

 

Cook time beeps

3

Cook Time Reminder Beeps for 30 Min.

 

 

 

Control lock

4

Control Unlocked

Scroll speed

5

Medium Speed

Volume level

6

6 bars

Temp C/F

7

Degrees F

Language

8

English

Default

9

Press AUTO SET for Factory Settings

Display On/Off

Clock

Clock Display is ON

Additional Options

12 HR Energy Saver OFF

Timer Reminder Beeps for 30 Min. No Timer Reminder Beeps

Cook Time Reminder Beeps for 5 Min. No Cook Time Reminder Beeps Control Locked

Fast Speed Slow Speed 1 to 8 bars

Degrees C French, Spanish N/A

Clock Display is OFF