(TROUBLE 3) No microwave oscillation even though fan motor rotates.
CONDITION |
| CHECK |
| RESULT |
| CAUSE |
|
|
|
|
|
|
|
REMEDY
No
microwave oscillation
Continuity |
Check continuity of high |
voltage fuse |
Replace high voltage fuse |
|
|
|
| Continuity |
Check continuity of high |
|
| ||
|
|
| ||
|
|
| ||
voltage capacitor terminals |
|
|
| |
with wires removed |
|
|
| |
|
|
|
|
|
Check continuity of high voltage |
|
|
|
| Continuity in |
|
|
|
| ||
rectifier in forward and backward |
|
|
| backward | |
direction with DC megger |
|
|
| direction | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Continuity |
Connect megger leads to mag- |
|
|
| ||
|
|
|
| ||
|
|
|
| ||
netron terminal and magnetron |
|
|
|
| |
body |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 Ω or ∞ |
Check resistance of primary and |
|
|
| ||
|
|
|
| ||
|
|
|
| ||
secondary coil of high voltage |
|
|
|
| |
transformer |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
Check continuity of magnetron |
|
|
| ||
|
|
| Continuity | ||
with wires removed |
|
|
|
| |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
Check continuity of filament termi- |
|
|
| ||
|
|
| Continuity | ||
nal of high voltage transformer |
|
|
|
| |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 V |
Check D.C. voltage being sup- |
|
|
| ||
|
|
|
| ||
|
|
|
| ||
plied to RELAY (RY1) coil |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Approx |
|
|
|
|
| |
|
|
|
|
| 15 VDC |
|
|
|
|
|
|
Defective high voltage trans- former
Defective high voltage rectifier
Defective mag-
netron
Defective high voltage trans- former
Defective mag-
netron
Defective high voltage trans- former
Defective touch
control circuit
Faulty
contacts or
RELAY (RY1)
or open
relay coil
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Replace
19