Daewoo KOR-63FB0S Component Test Procedure, High voltage transformer, High voltage capacitor

Models: KOR-63DB0S KOR-63DB9S KOR-63FB9S KOR-63FB0S

1 34
Download 34 pages 52.26 Kb
Page 24
Image 24
3.COMPONENT TEST PROCEDURE

3.COMPONENT TEST PROCEDURE

High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.

It is neither necessary nor advisable to attempt measurement of the high voltage.

Before touching any oven components or wiring, always unplug the oven from its power source and discharge the capacitor.

1.High voltage transformer

(1)Remove connections from the transformer terminals and check continuity.

(2)Normal readings should be as follows:

Secondary winding ...................Approx. 140±10% Filament winding....................................Approx. 0Primary winding .....................................Approx. 2

2.High voltage capacitor

(1)Check continuity of capacitor with meter on the highest OHM scale.

(2) A normal capacitor will show continuity for a short time, and then indicate 10Monce the capacitor is charged.

(3)A shorted capacitor will show continuous continuity.

(4)An open capacitor will show constant 10M.

(5)Resistance between each terminal and chassis should be infinite.

3.High voltage diode

(1)Isolate the diode from the circuit by disconnecting the leads.

(2)With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals. Reverse the meter leads and again observe the resistance reading.

Meter with 6V, 9V or higher voltage batteries should be used to check the front-back resistance of the diode, oth- erwise an infinite resistance may be read in both directions.

A normal diode’s resistance will be infinite in one direction and several hundred Kin the other direction.

4. Magnetron

For complete magnetron diagnosis, refer to “Measurement of the Microwave Power Output”. Continuity checks can only indicate and open filament or a shorted magnetron.

To diagnose for an open filament or a shorted magnetron.

(1)

Isolate magnetron from the circuit by disconnecting the leads.

(2)

A continuity check across magnetron filament terminals should indicate 0.1or less.

(3)A continuity check between each filament terminal and magnetron case should read open.

5.Fuse

If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and monitor switch before replacing the blown fuse.

In case the fuse is blown by an improper switch operation, replace the defective switch and fuse at the same time. Replace just the fuse if the switches operate normally.

23

Page 24
Image 24
Daewoo KOR-63FB0S Component Test Procedure, High voltage transformer, High voltage capacitor, High voltage diode, Fuse