TROUBLESHOOTING

TROUBLESHOOTING

Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized

service depot or Danby’s Toll Free Number for assistance: 1-800-26-PROBLEMPOSSIBLE CAUSESOLUTIONNOTES:(1-800-263-2629)

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

 

 

• Check connection of power cord to

 

 

power source.

 

• No power to the unit.

• Check fuse or circuit breaker.

1) Air conditioner will not operate.

• Set SELECTOR SWITCH to

 

 

position other than “OFF”.

 

 

• The power cord “RESET” button

 

 

must always be pushed in (engaged)

 

 

for correct operation.

 

 

 

 

• Dirty air filter.

• Clean/replace air filter.

 

• Unit size inappropriate for application

• Check with dealer to determine

2) Inefficient or no cooling.

• Blocked air flow.

proper unit capacity for application.

• Power interruption, settings changed

• Remove obstruction from grill or

 

 

too quickly, or compressor overload

outdoor louvres.

 

tripped.

• Turn the unit off and wait 5

 

 

minutes before attempting to restart.

 

 

 

3) Noisy unit

• Loose parts.

• Tighten loose parts.

• Inadequate support.

• Provide additional support to unit.

 

 

 

 

4) Odors

• Formation of mold, mildew, or algae

• Clean unit thoroughly.

on wet surfaces.

• Place algaecide tablet in base pan.

 

 

 

 

5) Water dripping outside

• Hot and humid weather.

• Condensation run-off is normal under

 

these conditions.

 

 

 

 

 

6) Water dripping inside

• Unit is not properly angled to allow

• Unit must be installed on an angle for

water to drain outside.

proper condensation run-off. Check

 

 

the unit and make any adjustments.

 

 

 

 

 

• When outdoor temperature is

 

• Low outside temperature

approximately 18.3°C (65°F) or

7) Ice or frost build-up.

below, frost may form when unit is in

• Unit air filter is dirty

cooling mode. Switch unit to FAN

 

 

 

(only) operation until frost melts.

 

 

• Remove and clean filter.

 

 

 

NOTES:

1)If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a qualified technician.

2)When unit is installed using proper installation steps, unit is properly tipped toward the outdoors to allow for condensation run-off.

9