Insert the 4- wire supply cord through both sections of the strain relief and re-install strain relief screws, do not fully tighten until electrical connections are complete.

Attach the power cord ground conductor (green wire) to the ground terminal marked with the ground symbol. Tighten screw until ground conductor is secure. (See Fig. 7)

Attach the power cord neutral conductor (white wire) to the neutral terminal. (marked N) Tighten screw until neutral conductor is secure. (See Fig. 7)

Attach the power cord phase conductor (black wire) to the phase terminal (marked L3). Tighten screw until power conductor is secure. (See Fig. 7)

Attach the power cord phase conductor (red wire) to the phase terminal (marked L1). Tighten screw until power conductor is secure.(See Fig. 7)

Tighten the screws on the strain relief so that the power cord cannot be moved.

Re-install the cover of the junction box and secure with four screws removed earlier.

The dryer is now ready to be connected to the power supply receptacle.

Three-wire connection

Junction box

Fig. 8

To connect power cord:

Remove the screws from the cover of the junction box located at the top rear of the dryer.

Loosen/remove the two screws on the strain relief clamp and remove from 3-wire supply cord.

The strain relief splits into two indentical parts.

Insert the large flange of both sections into the hole located on the left side of the junction box housing. The short flange of both sections and screws must remain positioned on the external side of the junction box housing.

Insert the 3- wire supply cord through both sections of the strain relief and re-install the strain relief screws, do not fully tighten until electrical connections are complete.

Attach the power cord ground conductor (green wire) to the ground terminal marked with the ground symbol. Tighten screw until ground conductor is secure. (See Fig. 8)

Attach the two remaining power cord phase conductors ( left = black wire and right = red wire ) to the phase terminals (marked L3 & L1). Tighten screws so that the power conductors are secure. (See Fig. 8)

Tighten the screws on the strain relief so that the power cord cannot be moved.

Re-install the cover of the junction box and secure with four screws removed earlier.

The dryer is now ready to be connected to the power supply receptacle.

Note:

The receptacle should be located so that the plug and receptacle will be accessible with the dryer in its installed position.

Additional Grounding Procedure

Some local codes may require a separate ground. In such cases, the required accessory ground wire, clamp and screw must be purchased separately.

Never ground the dryer to plastic plumbing lines, gas lines or hot water pipes.

8

Instructions for Use

Page 9
Image 9
Danby DCD5505W-1 manuel dutilisation Three-wire connection, Junction box