1.Is the water tank full?

Direct Drain

Garden Hose (not included)

Quick Connect

Fig. 19

CAUTION

During air conditioning and dehumidifying modes, if the compressor cycle is interupted (unplugged, power failure,etc.) and reinstated immediately thereafter, (within 3-5 minutes) a “compressor protection circuit” is automatically self-activated. The compressor cannot operate during “compressor protection” mode. (this is normal) It may take 3-5 minutes before the “protection circuit” self-deactivates.

DO NOT ATTEMPT TO START THE UNIT (COMPRESSOR) DURING THIS PERIOD. Upon re-starting the unit (turn 1/0 switch on) all program information(i.e. time, mode, fan speed, auto timed programs) will have to be re-programed.

CAUTION

Removal and/or partial displacement of the internal water tank will cause the compressor to stop operating (this is a safety feature). This condition will cause the unit to beep (20 seconds) and the (red) “water full” light remain illuminated until corrected. The compressor cannot operate during a “red” light condition. Check the following;

1.Is the water tank full?

Empty and re-install water tank.

2.Has the water tank been accidently displaced? Re-position water tank.

The “red” light will stop flashing automatically when the water tank has been emptied and/or correctly re-positioned.