OPERATION (cont’d)

OPERATION (cont’d)

AIR CONDITIONING

NOTE: The exhaust hose must be properly vented outdoors during air conditioning mode.

1)Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous set temperature will be shown in the temperature display area of the control panel.

Fig. A

2)Press the MODE key (Fig. B) until the COOL indicator light illuminates on the control panel (Fig.C). Each depression of the MODE key will advance to a different mode setting (Cool- Dehumidifier-Fan)

3)Press the appropriate increase AIR CONDITIONING or decrease DEHUMIDIFIER:buttons (Fig. D1 & D2) to select a suitable operating temperature setting. Temperature settings are adjustable between 16°C (61°F) to 32°C (89°F).

4)Press the FAN key (Fig. E) to select the desired fan speed setting (Auto-High- Med.-Low). Your selection will appear on the control panel (each depression of the fan key will advance to a different setting).

Cooling stops automatically when the set temperature is achieved. Cooling resumes when the room temp. rises above the “set” temperature level.

DEHUMIDIFIER:

NOTE: The exhaust hose does NOT have to be vented outdoors during dehumidifier mode.

1)Press the ON/OFF key pad to switch the unit on (Fig. A)

2)Press the MODE key (Fig. B) until the DRY indicator illuminates on the control panel (Fig. G).Each press of the MODE key will advance to a different mode setting (Cool-Dehumidifier-Fan).

3)If room temperature is 25°C (77°F), fan speed can be adjusted. Press the Fan key (Fig. E) to select the desired FAN SPEED setting. Your selection will appear on the contol panel. Each depression of the fan key will advance to a different fan speed (High- Med.- Low) as shown in Fig. F. Otherwise, fan speed is fixed to “low”.

Fig. B

Fig. C

Fig. D1

Fig. D2

Note: THE WARM AIR EXCHANGE HOSES MUST VENT INSIDE THE ROOM WHEN USING DEHUMIDIFY MODE, NOT OUTSIDE AS IT DOES WHEN COOLING.

IMPORTANT: The drain hose must be installed during dehumidifier mode.

Drain Hose (79” / 200cm)

FAN:

NOTE: During Fan Mode, the exhaust hose does NOT have to be vented outdoors.

1)Press the POWER SWITCH key pad to switch the unit on (Fig. A).

2)Press the MODE key (Fig. B) until the FAN indicator illuminates on the control panel (Fig. C). Each press of the MODE key will advance to a different mode setting (Cool- Dehumidifier-Fan).

3)Press the FAN Key (Fig. E) to select the desired FAN SPEED setting. Your selection will appear on the control panel. Each press of the fan key will advance to a different fan speed (High- Med- Low) as shown in Fig. F.

Fig. E

Fig. F

Fig. G