Setting 28x Printer Configuration Options

The following procedure tells how to change the 28x printer configuration to work with the printer driver for Windows 95 or 98. The instructions begin at the main menu of the printer’s display window.

Setting Customer Engineer Configuration Options

1.At the Datacard 28x printer front panel, press Esc to go to the Main Menu.

2.Press F3 to choose Set Up.

3.Select F3 to choose Customer Engineer.

4.When prompted for an access code, press F2 and then F1.

5.Press F1 to choose the configuration menu.

6.Verify and set the configuration options identified below. Use the function keys (F1, F2, and F3) to scroll through menus, select a menu, select menu options, and save options.

Configure Menu option

Value to select or enter

System Page Select

System Page Menu

 

Page = CPX Format

 

Use High Baud Rate = On

 

Baud Rate Menu

 

Baud = 57600

 

NAK Busy Used = On

 

Send Pause Status = On

 

 

Host Comm.

Data Bits and Parity Menu

 

Parity = 8 bit None

 

Ignore Transmit Error = On

 

Use Comm. Translation Table = Off

 

 

Check Card Limits Error

Card Limits Error = On

 

 

For 486-based workstations and below, in the System Page Select Menu, choose Use High Baud Rate = OFF and in the Host Comm. Menu choose Baud Rate = 19200.

7.Press Esc twice to return to the Set Up Menu.

Windows 95 and 98 Printer Driver Installation and Technical Reference

13

Page 17
Image 17
Datacard Group 28X, 150I, 450 Setting 28x Printer Configuration Options, Setting Customer Engineer Configuration Options