1

DS1500

 

1.5TEST KEY FUNCTIONING

DS1500 provides an external key, which can be used for the following:

-Restoring dual RS232 interface at power on

-Activating Test Mode from the current operating mode

1.5.1Restoring Dual RS232 Interface

To launch the Restoring Dual RS232 Interface function, proceed as follows:

1.Press the Test key before powering the scanner on;

2.Power ON the scanner while keeping the Test key pressed;

3.When the TX Data/ACT LED switches on, the function is activated;

4.When the TX Data/ACT LED switches off, the restore default of the RS232 interface is achieved;

5.The Test key can be released.

If the Test key is released before the TX Data/ACT LED is off, the Restoring Dual RS232 is not executed.

To restart the procedure, it is first necessary to switch off the DS1500 scanner.

The Restore Dual RS232 is not permanently saved.

NOTE