TROUBLESHOOTING

5

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

Problem

Suggestions

Reading:

Check synchronization of reading pulse with object to read

Not possible to read

Is the scan line correctly positioned?

the target barcode

Place barcode in the center of scan line and run TEST

(always returns No

MODE (by WinHost as an Operating Mode or by the

Read)

external key, see par. 1.5.2).

 

If you still have trouble, check the following:

 

Is the reading distance within that allowed (see

 

reading diagrams)?

 

Is the Tilt angle too large?

 

Is the Skew angle less than 10° (direct reflection)?

 

Choose the CODE tab and enable different code

 

types (except Pharmacode). LENGTH = Variable

 

Is the Bar Code quality sufficient?

 

If you had no success, try to perform the test using the

 

BARCODE TEST CHART.

 

 

Communication:

Is the cable connected?

Device is not

Is the correct wiring respected?

transmitting anything

Are serial host settings equivalent to the serial device

to the host

setting?

 

 

Communication:

In the WinHost program select the DATA FORMAT

Data transferred to

tab and check for values of HEADER, TERMINATOR,

the host are

SEPARATOR, FILL CHARACTERS

incorrect, corrupted

Also check the CODE FIELD LENGTH value

or incomplete

Are the COM port parameters correctly assigned?

 

 

Communication:

Contact your local Datalogic office or Datalogic

Always returns the

Partner or ARC, because either a Motor or Laser

Reader Failure

failure has occurred.

Character (<BEL>

Note the exact model and Serial Number of the device

char as default)

 

How do I obtain my

The device’s serial number is printed on a label that is

units’ serial

affixed to the body of the reader.

numbers?

Serial numbers consist of 9 characters: one letter, 2

 

numbers, and another letter followed by 5 numbers.

 

 