2.6.3RS232 Master/Slave
The RS232 master/slave connection is used to collect data from several scanners to build either a
The Slave scanners use RS232 only on the main and auxiliary serial interfaces. Each slave DS1500 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the Master.
The Master scanner is connected to the Host on the main serial interface. The main interface type for the master scanner is RS232.
There is a single reading phase and a single message from the master scanner to the Host computer.
Either
When
The main and auxiliary ports are connected as shown in the figure below.
DS1500
Slave
DS1500 | 2 | 1 |
|
Slave
1
2
DS1500
Master
|
|
| 3 |
1 | Main serial interface | Host | 1 |
| |||
|
| ||
2 | Auxiliary serial interface |
|
|
3 | External Trigger (for |
|
|
Figure 21 – RS232 Master/Slave Layout