Technical Specifications

 

 

 

 

 

 

Item

Description

 

 

 

 

 

 

 

Print Contrast Minimum

15% minimum reflectance

 

 

 

 

 

UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian

 

 

Pharmacode 39; Code 128; C128 ISBT; Code 128 add-

 

Decode Capability

ons; I 2 of 5; Standard 2 of 5; Code 11;Codabar; EAN

 

128; Code 93; MSI; GS1 DataBar™ Omnidirectional,

 

 

 

 

GS1 DataBar™ Limited, GS1 DataBar™ Expanded;

 

 

Code4, Code5.

 

 

 

 

 

RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS,

 

 

IBM 46xx (ports5B and 9B), USB Com Std., USB Key-

 

 

board, USB Alternate Keyboard, USB OEM, Keyboard

 

Interfaces Supportedd

Wedge (AT with or w/o Alternate Key, IBM AT PS2

 

with or w/o Alternate Key, PC-XT, IBM 3153, IBM Ter-

 

 

 

 

minals 31xx, 32xx,34xx, 37xx make only and make

 

 

break keyboard, Digital Terminals VT2x, VT3xx,

 

 

VT4xx, and Apple) and Wand Emulation.

 

 

 

 

User Environment

 

 

 

 

 

Operating Temperature

32° to 122° F (0° to 50° C)

 

 

 

 

Charging Temperature

32° to 104° F (0° to 40° C)

 

 

 

 

Storage Temperature

-4° to 158° F (-20° to 70° C)

 

 

 

 

Humidity

Operating: 5% to 90% relative humidity,

 

non-condensing

 

 

 

 

 

 

Drop Specifications

Scanner withstands 18 drops from 1.8 meters

 

(5.9 feet) to concrete

 

 

 

 

 

 

Ambient Light Immunity

Up to 100,000 Lux

 

 

 

 

Contaminants Spray/rain

IEC 529-IP52 (scanner only)

 

Dust/particulates

 

 

 

 

 

 

ESD Level

16 KV

 

 

 

 

a.Charge Times are much lower when battery is within daily typical operat- ing condition.

b.Typical input current measured under factory default configuration.

c.13 mils DOF based on EAN. All others are Code 39. All labels grade A, typi- cal environmental light, 20°C, label inclination 10°

d.See Interface Selection on page 22 for a listing of available interface sets by model type.

Quick Reference Guide

35

Page 39
Image 39