Default Settings
The following tables contain the default values for the major barcode setup
parameters, according to the type of scan engine mounted on the mobile computer.
For a complete list of parameters and of their configuration procedures, please refer
to the SDK Help file on the CD.
SCAN PARAMETERS
ScanTimeout 5000
GoodReadSound Beep.wav
LedDuration 200 mS
LedPulses 1
ContinuousMode Disabled
KeyboardEmulation Enabled
SoftTrigger Enabled
ScanAlwaysOn Disabled
GreenSpotDuration 1000
NotPrintableChar Leave
ScanButton Enable
BARCODE SYMBOLOGY
SPECIFIC READER PARAMETERS
UPC A Enabled
UPC E Enabled
EAN 8 Enabled
EAN 13 Enabled
Code 39 Enabled
Code 39 Full ASCII Disabled
Code 32 Disabled
2/5: Interleaved Enabled
2/5: Industrial Disabled
2/5: Matrix Disabled
Code 128 Enabled
EAN 128 Enabled
Codabar Enabled
BARCODE SYMBOLOGY
SPECIFIC READER PARAMETERS
MSI Enabled
Plessey Disabled
Code 93 Disabled
Code 11 Disabled