Nikon D1H

•With the camera power off, connect the EH-4 AC adapter. The AC adapter is required for sensor inspection and cleaning.

•Turn the power on and press the Menu button.

•Use the multi selector to scroll to the CSM menu and select 8. Mirror Lock-up.

•Press the multi selector to the right to open the Mirror Lock-up for CCD Cleaning sub menu.

•Highlight ON CCD Cleaning and press the multi selector to the right. The mirror will lock up and the shutter will remain open.

•Remove the camera lens.

•The mirror and shutter can be reset by selecting OFF in the Mirror Lock-up CCD Cleaning sub menu.

Nikon D2H

•With the camera power off, connect the EH-6 AC adapter. The AC adapter is required for sensor inspection and cleaning.

•Turn the power on and press the Menu button.

•Use the multi selector to scroll to the Set Up menu and select Mirror Lock-up.

•Press the multi selector to the right to open the Mirror Lock-up sub menu.

•Press the multi selector to the right to select Start.

•Press the shutter button. The mirror will lock up and the shutter will remain open until the power is turned off

•Remove the camera lens.

•Turning the power off will reset the mirror and shutter.

Olympus

Olympus E-1

•Make sure the battery is fully charged.

•Turn the power on and press the Menu button.

•Scroll to the tools1 menu and highlight Cleaning Mode.