Table 1-3. LCD Status Messages (continued)
Line 1 | Line 2 | Causes | Corrective Actions |
Message | Message |
|
|
|
|
|
|
E0276 | VRM # PG | The voltage of the specified VRM | See "Troubleshooting the |
|
| is out of acceptable range. | Microprocessors" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. If the problem still |
|
|
| persists, see "Getting Help" |
|
|
| in your Installation |
|
|
| and Troubleshooting Guide. |
|
|
|
|
E0276 | VCACHE # PG | The voltage of the specified | See "Troubleshooting the |
|
| VCACHE is out of acceptable | Microprocessors" in your |
|
| range. | Installation and Troubleshooting |
|
|
| Guide. If the problem still |
|
|
| persists, see "Getting Help" |
|
|
| in your Installation |
|
|
| and Troubleshooting Guide. |
|
|
|
|
E0276 | PS AC CURRENT | Power supply AC current is out | See "Troubleshooting Power |
|
| of acceptable range. | Supplies" in your Installation |
|
|
| and Troubleshooting Guide. |
E0276 | PS OVER CURRENT Power supply current is out |
| of acceptable range. |
See "Troubleshooting Power Supplies" in your Installation and Troubleshooting Guide.
E0412 RPM FAN PS BLANK Power supply fan RPM is out of acceptable range.
See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.
E0412 | RPM FAN n | Specified cooling fan is faulty, | See "Troubleshooting System |
| FAN REDUNDANCY | improperly installed, or missing. | Cooling Problems" in your |
|
| Installation and Troubleshooting | |
| LOST |
| |
|
| Guide. | |
|
|
| |
|
|
|
|
E0780 | PROC # CONFIG | The specified processor has | See "Troubleshooting the |
| ERR | a configuration error. | Microprocessors" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
|
|
|
|
E0780 | PROC # DISABLED | The specified processor is | See "Troubleshooting the |
|
| disabled. | Microprocessors" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
Information Update
9