Reconfiguring the System for Regional Power Requirements

Reconfiguring the System for Regional Power Requirements

CAUTION: If you relocate a system operating in the 120–127 VAC or 200–240 VAC range to a different geographic area, ensure that jumper CB_TYPE matches the AC line voltage range of your new location.

If the new power source is less than 120 VAC and you do not reconfigure jumper CB_TYPE for the lower voltage power source, damage to the system power cable or the system itself may occur.

Table 1-1lists countries where the AC line voltage may be less than 120 V. Confirm the power source in your particular location and reconfigure the CB_TYPE jumper if necessary.

Table 1-1. Areas Where AC Line Voltage May Be Less Than 120 V

AC Line Voltage

Country

 

 

100 V

Japan, Korea, Okinawa

105 V

Korea

110 V

Anguilla, Azores, Belgium, Belize, Bolivia, Brazil, Colombia, Curacao, Dominican

 

Republic, Ecuador, El Salvador, France, Guam, Guyana, Haiti, Honduras, Jamaica,

 

Lebanon, Panama, Peru, Philippines, Somalia, Surinam, Tahiti, Taiwan, Turkey, Virgin

 

Islands

115 V

Aruba, Barbados, North Mariana Island, St. Pierre & Miquelon, Surinam, Tonga,

 

Trinidad & Tobago

 

 

Table 1-2 and Figure 1-1 show the settings and location of the CB_TYPE jumper.

Table 1-2. Power Configuration Jumper Settings

Jumper

Setting

Description

 

 

 

CB_TYPE

 

AC line voltage is 120 V or greater*

 

(default)

AC line voltage is less than 120 V

* This jumper is not functional for systems using a line voltage in the range of 200–240 VAC.