Table 1-3. LCD Status Messages (continued)
Line 1 | Line 2 | Causes | Corrective Actions |
Message | Message |
|
|
|
|
|
|
E0880 | PS REDUNDANCY | Power supply redundancy has | Reinstall the power supply |
| LOST | been lost because a power supply | to restore redundancy. |
|
| has been removed from the |
|
|
| system. |
|
|
|
|
|
E0D76 | BP DRIVE n | Faulty or improperly installed | See "Troubleshooting SCSI Hard |
|
| hard drive or RAID controller. | Drives," "Troubleshooting a RAID |
|
|
| Controller Card," and |
|
|
| "Troubleshooting the Integrated |
|
|
| RAID Controller" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
E0D76 | 1x2 Drive n | The specified drive on the 1x2 |
|
| backplane is faulty or improperly |
|
| installed, or the RAID controller |
|
| is faulty or improperly installed. |
See "Troubleshooting SCSI Hard Drives," "Troubleshooting a RAID Controller Card," and "Troubleshooting the Integrated RAID Controller" in your Installation and Troubleshooting Guide.
E0D76 | SCSI CONNECTOR | SCSI cable is not connected. |
See "Troubleshooting SCSI Hard Drives" in your Installation and Troubleshooting Guide.
EB107 | PROC BUS PERR | Faulty or improperly installed | See "Troubleshooting the |
| PROC INIT ERR | microprocessor or system board. | Microprocessors" in your |
| PROC PROTOCOL |
| Installation and Troubleshooting |
| ERR |
| Guide. |
|
|
| If the problem persists, see |
|
|
| "Getting Help" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. |
|
|
|
|
EB107 | PROC MACHINE CHK | Faulty or improperly installed | See "Troubleshooting the |
|
| microprocessor or system board. | Microprocessors" in your |
|
|
| Installation and Troubleshooting |
|
|
| Guide. If the problem persists, |
see "Getting Help" in your Installation and Troubleshooting Guide.
EB107 | PROC HOT | Processor is out of acceptable |
|
| temperature range and has halted |
|
| operation. |
See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.
Information Update
11