Table 1-3. LCD Status Messages (continued)

Line 1

Line 2

Causes

Corrective Actions

Message

Message

 

 

 

 

 

 

E0880

PS REDUNDANCY

Power supply redundancy has

Reinstall the power supply

 

LOST

been lost because a power supply

to restore redundancy.

 

 

has been removed from the

 

 

 

system.

 

 

 

 

 

E0D76

BP DRIVE n

Faulty or improperly installed

See "Troubleshooting SCSI Hard

 

 

hard drive or RAID controller.

Drives," "Troubleshooting a RAID

 

 

 

Controller Card," and

 

 

 

"Troubleshooting the Integrated

 

 

 

RAID Controller" in your

 

 

 

Installation and Troubleshooting

 

 

 

Guide.

E0D76

1x2 Drive n

The specified drive on the 1x2

 

 

backplane is faulty or improperly

 

 

installed, or the RAID controller

 

 

is faulty or improperly installed.

See "Troubleshooting SCSI Hard Drives," "Troubleshooting a RAID Controller Card," and "Troubleshooting the Integrated RAID Controller" in your Installation and Troubleshooting Guide.

E0D76

SCSI CONNECTOR

SCSI cable is not connected.

See "Troubleshooting SCSI Hard Drives" in your Installation and Troubleshooting Guide.

EB107

PROC BUS PERR

Faulty or improperly installed

See "Troubleshooting the

 

PROC INIT ERR

microprocessor or system board.

Microprocessors" in your

 

PROC PROTOCOL

 

Installation and Troubleshooting

 

ERR

 

Guide.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" in your

 

 

 

Installation and Troubleshooting

 

 

 

Guide.

 

 

 

 

EB107

PROC MACHINE CHK

Faulty or improperly installed

See "Troubleshooting the

 

 

microprocessor or system board.

Microprocessors" in your

 

 

 

Installation and Troubleshooting

 

 

 

Guide. If the problem persists,

see "Getting Help" in your Installation and Troubleshooting Guide.

EB107

PROC HOT

Processor is out of acceptable

 

 

temperature range and has halted

 

 

operation.

See "Troubleshooting System Cooling Problems" in your Installation and Troubleshooting Guide.