Interpreting the output: To verify that the ATM interface is operational, check the fol- lowing items:

￿The UNI configured version and UNI operating version. This value should be 3.1 in both cases.

￿The SSCOP operational state. This should indicate that the UNI is oper- ational. If you see inoperational instead, the ATM card is improperly connected to the network or the switch is improperly configured.

￿The Primary ATM address. This should be a valid ATM address for your network. If you see an address consisting entirely of zeros, the ATM card is either improperly connected to the network, or there might be a configuration problem.

$￿￿￿￿￿"￿￿￿￿￿￿￿￿￿￿￿$￿￿￿￿￿￿￿￿￿

For the filer to participate in an ELAN, you must configure the ATM adapter with the address of the LECS. The LEC joins an ELAN by first exchanging configuration infor- mation with the LECS. The LECS then supplies the client with the ATM address for the LES.

To configure the LECS address, perform the following steps:

1.Set the LECS address.

2.Check that the adapter is communicating with the LECS.

8 Dell PowerVault 7x0N Systems — Connecting to ATM and FDDI Networks