Troubleshooting
This appendix provides troubleshooting information for your cluster configuration. Table
Table
Problem | Probable Cause | Corrective Action |
|
|
|
The nodes cannot | The storage system is | Ensure that the cables are connected |
access the storage | not cabled properly to | properly from the node to the storage |
system, or the | the nodes or the | system. See "Cabling Your Cluster for |
cluster software is | cabling between the | Public and Private Networks" on |
not functioning | storage components is | page 17 for more information. |
with the storage | incorrect. |
|
system. |
|
|
| The length of the | Ensure that the fibre optic cables do |
| interface cables | not exceed 300 m (multimode) or 10 |
| exceeds the maximum | km (single mode |
| allowable length. | connections only). |
| One of the cables is | Replace the faulty cable. |
| faulty. |
|
| Access Control is not | Verify the following: |
| enabled correctly. | • All switched zones are configured |
|
| |
|
| correctly. |
|
| • The Access Control software is |
|
| enabled on the storage system. |
|
| • All LUNs and hosts are assigned to |
|
| the proper storage groups. |
| The cluster is in a | Verify the following: |
| SAN, and one or more | • Each zone contains only one initiator |
| zones are not | (Fibre Channel daughter card). |
| configured correctly. | |
|
|