Current consumption: 10 A – 5 A (X 2) (per 750 W AC Power Supply Unit)
NOTE: (X #), # = Maximum number of power supplies per system.
Technical Specifications
NOTE: The following specifications are only those required by law to ship with your system. For a complete and
current listing of the specifications for your system, go to support.dell.com.
Power
AC Power Supply (per power supply)
Wattage 750 W
Heat dissipation
NOTE: Heat dissipation is calculated using the
power supply wattage rating.
2891 BTU/hr maximum
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a phase to
phase voltage not exceeding 230 V.
100 V AC to 240 V AC, autoranging, 50 Hz/60 Hz
Battery 3 V CR2032 Lithium ion coin cell
Physical
Height 87.3 mm (3.44 inch)
Width
With rack latches 482.4 mm (18.98 inch)
Without rack latches 444 mm (17.48 inch)
Depth (includes bezel) 755.8 mm (29.75 inch)
Weight (maximum) 32.5 kg (71.5 lbs)
Weight (empty) 18.78 kg (41.4 lbs)
Environmental
NOTE: Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data centers. For more
information, see the

Owner's Manual

at dell.com/support/manuals.
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Maximum Temperature Gradient (Operating and
Storage)
20 °C/h (36 °F/h)
Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)