Error Code Message Information
TMP0130 Message The control panel temperature is less than the lower warning
threshold.
LCD Message Control panel temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0132 Message The control panel temperature is greater than the upper warning
threshold.
LCD Message Control panel temperature is outside of range.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0134 Message The control panel temperature is outside of the allowable range.
LCD Message Control panel temperature is outside of range.
Details Ambient air temperature is too warm or cool.
Action Check the system operating environment and review event log for fan
failures.
VLT0100 Message Processor module <
name
> voltage is less than the lower warning
threshold.
LCD Message Processor module <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action 1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
3. If the issue persists, see Getting Help.
VLT0101 Message Processor module <
name
> voltage is less than the lower critical
threshold.
LCD Message Processor module <
name
> voltage is outside of range.
127