Step 8: (Optional) Set Up In-Band Management
Out-of-band management (see Step 1: Discover the Storage Array (Out-of-band Management Only) ) is the
recommended method for managing the storage array. However, to optionally set up in-band management, use the
steps shown below.
The default iSCSI host port IPv4 addresses are displayed below for reference:
Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP:
192.168.131.101
Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP:
192.168.133.101
Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP:
192.168.131.102
Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP:
192.168.133.102
NOTE: The management station you are using must be configured for network communication to the same IP
subnet as the PowerVault MD3660i host ports.
1. Establish an iSCSI session to the PowerVault MD3660i RAID storage array.
2. Restart the SMagent service.
3. Launch MD Storage Manager.
If this is the first storage array to be set up for management, the Add New Storage Array window is displayed.
Otherwise, click New.
4. Select Manual and click OK.
5. Select In-band management and enter the host server name(s) or IP address(es) of the host server that is running
the PowerVault MD Storage Manager.
6. Click Add.
In-band management should now be successfully configured.
44