Yamaha RX-V4600 Troubleshooting for the auto setup procedure, Before auto setup, Error message

Models: RX-V4600

1 126
Download 126 pages 29.82 Kb
Page 35
Image 35

AUTO SETUP

Troubleshooting for the auto setup procedure

Before auto setup

Error message

Cause

Remedy

 

 

 

Connect MIC!

Optimizer microphone is not connected.

• Connect the supplied optimizer microphone to the

 

 

OPTIMIZER MIC jack on the front panel.

 

 

 

Unplug Phones!

Headphones are connected.

• Unplug the headphones.

 

 

 

No Setup Menu!

No setup menu items have been selected.

• Select at least one setup menu item.

 

 

 

Memory Guard!

This setting is protected.

• Remove the protection setting for auto setup

 

 

(see page 68).

 

 

 

During auto setup

Press l / h to display detailed information for individual errors. Select Retry to try the auto setup procedure again.

Error message

Cause

Remedy

 

 

 

E01:No Front SP

Front L/R channel signal(s) is (are) not

• Select the front speakers by pressing

 

detected.

SPEAKERS A or B on the front panel

 

 

(or by setting AMP/SOURCE/TV to AMP,

 

 

then pressing SPEAKERS A or B on the remote

 

 

control).

 

 

• Check the front L/R speaker connections.

 

 

 

E02:No Sur. SP

Only one surround channel signal is detected.

• Check the surround speaker connections.

 

 

 

E03:No Pres. SP

Only one presence channel signal is detected.

• Check the presence speaker connections.

 

 

 

E04:SBR ->SBL

Only the surround back right channel signal is

• Connect the surround back speaker to the LEFT

 

detected.

SURROUND BACK SPEAKERS terminal if you

 

 

only have one surround back speaker.

 

 

 

E05:Noisy

Background noise is too loud.

• Try auto setup in a quiet environment.

 

 

• Turn off noisy electric equipment like air

 

 

conditioners, or move them away from this unit.

 

 

 

E06:Check Sur.

Surround back speaker(s) is (are) connected,

• Connect surround speakers when using (a) surround

 

though surround L/R speakers are not.

back speaker(s).

 

 

 

E07:No MIC

The optimizer microphone was unplugged

• Connect the supplied optimizer microphone to the

 

during the auto setup procedure.

OPTIMIZER MIC jack on the front panel.

 

 

 

E08:No Signal

The optimizer microphone does not detect test

• Check the microphone setting.

 

tones.

• Check the speaker connections and placement.

 

 

 

E09:User Cancel

The auto setup procedure was cancelled

• Perform the auto setup procedure again.

 

because a setting that affects auto setup (such as

 

 

changing speaker settings, etc.) was changed

 

 

during the procedure.

 

 

 

 

E10:Internal Err

An internal error occurred.

• Restart this unit, then try the auto setup procedure

 

 

again.

 

 

 

PREPARATION

31

Page 35
Image 35
Yamaha RX-V4600 Troubleshooting for the auto setup procedure, Before auto setup, During auto setup, Error message, Cause