Yamaha RX-V4600 owner manual Confirming the results, If you set Setup Type to “Auto”

Models: RX-V4600

1 126
Download 126 pages 29.82 Kb
Page 34
Image 34

AUTO SETUP

Confirming the results

You can confirm the results of each analysis.

If you set Setup Type to “Auto”

The results are displayed after all items have been analyzed.

Setup Menu

 

Retry

Setup Type

Exit

Detail

 

Setup

 

 

Start

Measurement Over

 

Successfully

Press n and select Setup to set the measured values.

Press k and select Retry to retry the auto setup procedure.

Press h and select Detail to view information about measurement results and warning messages. For more details about warning messages, see “Troubleshooting for the auto setup procedure” on page 31.

Press l and select Exit to exit from the auto setup procedure. If you select Exit, “Don’t Setup?” appears on the screen. To set the measured values and exit, select Yes. To cancel the settings and exit, select No.

If you set Setup Type to “Step”

The results are displayed individually after each analysis.

Distance

Retry

Exit Detail

Size

Next

Equalizing

Level

Result

Press n and select Next to start measurement of the next menu item.

Press k and select Retry to retry the auto setup procedure.

Press h and select Detail to view information about measurement results and warning messages. For more details about warning messages, see “Troubleshooting for the auto setup procedure” on page 31.

Press l and select Exit to exit from the auto setup procedure. If you select Exit, “Don’t Setup?” appears on the screen. To set the measured values and exit, select Yes. To cancel the settings and exit, select No.

After all menu items have been measured, “Measurement Over” appears on the screen and the results for each item are displayed.

Press n and select Setup to set the measured values.

Press k and select Retry to retry the auto setup procedure.

Press h and select Detail to view information about measurement results and warning messages. For more details about warning messages, see “Troubleshooting for the auto setup procedure” on page 31.

Press l and select Exit to exit from the auto setup procedure. If you select Exit, “Don’t Setup?” appears on the screen. To set the measured values and exit, select Yes. To cancel the settings and exit, select No.

y

If you want to make more detailed settings, change the system parameters using the Manual Setup menu. If you want to return to the Auto Setup settings after making settings in the Manual Setup menu, navigate to the Information screen in the Auto Setup menu, press k / n repeatedly to select the parameter you want to adjust, then press ENTER.

Notes

If you change speakers, speaker positions, or the layout of your listening environment, perform auto setup again to re-calibrate your system.

Depending on your listening environment, SubWfr:REV may appear in the Wiring results. In this case, SWFR Phase in the Manual Setup menu (see page 64) is automatically set to Reverse. To select the desired setting, change the SWFR Phase parameter in the Manual Setup menu.

In the Distance results, the distance displayed may be longer than the actual distance depending on the characteristics of your subwoofer. This may also be the case when using an external amplifier.

In the Equalizing results, different values may be set for the same band to provide finer adjustments.

30

Page 34
Image 34
Yamaha RX-V4600 owner manual Confirming the results, If you set Setup Type to “Auto”, If you set Setup Type to “Step”