Dell R515 RAID Configurations 12 HDD Chassis, Ass-X, ASSR1/R5, RAID1 + RAID5 Perc H700, Sata

Models: R515

1 63
Download 63 pages 53.04 Kb
Page 41
Image 41

Dell

 

 

 

 

Mixed SAS + SATA

 

 

 

 

 

 

(must be all 3.5" HDDs)

 

 

 

 

 

 

(ex. Min 2 x SAS + 2 x SATA;

 

Mixed HDD (SAS + SATA) Factory Configuration

max 2 x SAS + 6 x SATA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

 

 

 

 

 

Type

#

Name

Description

 

 

HDD

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 +

 

2 +

 

 

C10

ASS-X

No RAID (PERC H200)

 

2

 

6

 

 

 

 

 

 

 

 

 

 

Mix HDD (Add-in

 

ASSR1/R5-

 

 

3 +

 

2 +

 

card)

C11

X

RAID1 + RAID5 (PERC H700)

 

3

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mixed SSD + SAS

 

 

 

 

 

 

(must be all 2.5" HDDs)

 

 

 

 

 

 

(ex. Min 2 x SSD + 2 x SAS;

 

Mixed HDD (SSD + SAS) Factory Configuration

max 2 x SSD + 6 x SAS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

 

 

 

 

 

 

Type

#

Name

Description

 

 

HDD

 

HDD

 

 

 

 

 

 

 

 

 

 

 

Mix HDD (Add-in

 

 

 

 

2 +

 

2 +

 

card)

C12

ASS-X

No RAID (PERC H200)

 

2

 

6

 

 

 

 

 

 

 

 

 

 

 

Table 18. RAID Configurations (12 HDD Chassis)

 

 

 

 

 

 

 

 

 

No Mixed HDD

 

 

 

 

 

 

 

 

 

 

 

(must be all 2.5" or 3.5"

 

 

Factory Configuration

 

 

HDDs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

Type

 

 

#

 

Name

 

Description

 

 

HDD

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No RAID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Add-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card)

 

 

C3

 

ASS

 

No RAID (PERC H200)

 

1

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C4

 

ASSR0

 

RAID0 (PERC H200, PERC H700)

 

2

 

12

 

 

RAID (Add-

 

 

 

 

 

 

 

 

in card)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C6

 

ASSR10

 

RAID10 (PERC H200, PERC H700)

 

4

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C7

 

ASSR5

 

RAID5 (PERC H700)

 

3

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C8

 

ASSR6

 

RAID6 (PERC H700)

 

4

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C9

 

ASSR1/R5

 

RAID1 + RAID5 (PERC H700)

 

2 + 3

 

2 + 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mixed SAS + SATA

 

 

 

 

 

 

 

 

 

 

 

(must be all 3.5" HDDs)

 

 

 

 

 

 

 

 

 

 

(ex. Min 2 x SAS + 2 x

 

 

 

 

 

 

 

 

 

 

SATA; max 2 x SAS + 6 x

 

 

Mixed HDD (SAS + SATA) Factory Configuration

SATA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

 

Max

 

 

Type

 

 

#

 

Name

 

Description

 

 

HDD

 

HDD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mix HDD

 

 

C10

 

ASS-X

 

No RAID (PERC H200)

 

2 + 2

 

2 + 10

 

 

(Add-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

card)

 

 

 

 

ASSR1/R5-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C11

 

X

 

RAID1 + RAID5 (PERC H700)

 

3 + 3

 

2 + 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

PowerEdge R515 Technical Guide

Page 41
Image 41
Dell R515 manual RAID Configurations 12 HDD Chassis, Ass-X, ASSR1/R5, RAID1 + RAID5 Perc H700, Sata