Installing System Components 113
Figure 3-20. Installing a Storage Controller Card
3
Slide the storage controller’s card edge connector into the card slot on the
riser until the card is fully seated. See Figure3-20.
4
Connect the SAS_0 cable to the storage controller’s SAS_0 connector, and
connect the SAS_1 cable to the controller’s SAS_1 connector.
NOTE: Be sure to connect the cable according to the connector labels on the
cable. The cables are not operational if reversed.
5
For a battery-cached PERC controller, install the RAID battery. See
"Installing a RAID Battery."
1 dedicated storage controller card
connector
2riser 1
3 integrated storage controller card 4 RAID battery connector (PERC only)
5 SAS_1 connector 6 connector locking tabs
7 SAS_0 connector 8 card edge guides (2)
8
3
6
2
7
1
5
4