34 About Your System
E201A SuperIO
failure.
Power cycle
AC.
SIO failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201B Keyboard
Controller
error. Power
cycle AC.
Keyboard controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201C SMI
initializatio
n failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201D Shutdown test
failure.
Power cycle
AC.
BIOS shutdown test failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory."
If the problem persists,
see "Getting Help."
E2020 CPU
configuration
failure.
Check screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting the
Processor(s)."
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory".
Table 1-1. LCD Status Messages (continued)
Code Text Cause Corrective Actions