LED Indicators

 

• One single-color LED indicator for drawer 2 fault status

Drawer

• One single-color LED indicator for sideplane card and power status

 

• One single-color LED indicator for drawer fault status

 

• One single-color LED indicator for logical fault status

 

• One single-color LED indicator for cable fault status

 

• Six single-color LED indicators for data transfer status

Disk Drive In Carrier

One single-color LED for drive fault status

(DDIC)

 

6 Gb SAS IO module

14 one-color LED status indicators, four each for the three SAS ports and two

 

for the module status

Cooling module

• One single-color LED indicator for module status

 

• One single-color LED indicator for battery fault status (not currently used)

 

• One single-color LED indicator for fan fault status

Power Supply Unit (PSU) • One single-color LED indicator for PSU fault status

One single-color LED indicator for AC power fault status

One single-color LED indicator for power status

Power Supplies

AC power supply (per power supply)

Wattage

2.8 kW

Voltage

200–240 VAC (16 A)

Heat dissipation

191-147 W

Input frequency

50/60 Hz

Max input power

1791 VA

Input current

7.4 A@241 VAC

Maximum inrush current

Under typical line conditions and over the entire system ambient operating

 

range, the inrush current may reach 55 A per power supply for 10 ms or less

 

Available Hard Drive Power (per Slot)

 

 

Supported hard drive

Up to 1.16 A at +5 V

power consumption

Up to 1.6 A at +12 V

(continuous)

 

 

 

I/O Card Power (per Slot)

 

 

 

Maximum power

11 W at +12 V

consumed by I/O Card

 

Maximum available

100 W at +12 V

power

 

21

Page 21
Image 21
Dell SCv2080 manual Ddic