Front-End Cabling
The storage system connects to switches or connects directly to a host server, depending on the type of
•A storage system with Fibre Channel
•A storage system with iSCSI
•A storage system with a SAS
In addition, the MGMT port on each storage controller connects to an Ethernet switch on the management network. This connection to the management network allows configuration, administration, and management of the Storage Center.
For more information, see the Dell Storage Center SCv2080 Storage System Deployment Guide.
Cabling SAN-Attached Host Servers
An SCv2080 storage system with Fibre Channel or iSCSI
NOTE: The left storage controller is storage controller 1 and the
1.Connect each host server to the switches.
2.Connect fault domain 1 to switch 1.
a.Connect a cable from storage controller 1: port 1 to switch 1.
b.Connect a cable from storage controller 2: port 1 to switch 1.
c.(Four port I/O card only) Connect a cable from storage controller 1: port 3 to switch 1.
d.(Four port I/O card only) Connect a cable from storage controller 2: port 3 to switch 1.
3.Connect fault domain 2 to switch 2.
a.Connect a cable from storage controller 1: port 2 to switch 2.
b.Connect a cable from storage controller 2: port 2 to switch 2.
c.
d.
12