Figure 7. Interconnected Storage Controllers
1. | SCv2080 storage system | 2. | Storage controller 1 |
3.Storage controller 2
Cabling an Expansion Enclosure to a Storage System
An SCv2080 storage system supports one SC180 expansion enclosure.
Use SAS cables to connect an SC180 expansion enclosure to an SCv2080 storage system.
NOTE: In an SCv2080 storage system, the left storage controller is storage controller 1 and the right storage controller is storage controller 2.
1.Connect a SAS cable from storage controller 1: port A to the expansion enclosure: left EMM, port C.
2.Connect a SAS cable from storage controller 2: port B to the expansion enclosure: left EMM, port B.
3.Connect a SAS cable from storage controller 2: port A to the expansion enclosure: right EMM, port C.
4.Connect a SAS cable from storage controller 1: port B to the expansion enclosure: right EMM, port B.
16