website at support.dell.com.

Ta b l e 1 - 3 . P C I / P C I - X S l o t A s s i g n m e n t s f o r Po w e r E d g e C l u s t e r N o d e s ( c o n t in u e d )

PowerEdge

PCI Buses

RAID Controller

NICs

DRAC II or III

System

 

 

 

 

 

 

 

 

 

2500

Bus 1: PCI slots 6

Install in any available

Install in any available 64-bit PCI slot.

If you are currently

 

and 7 are 32 bit,

PCI slot.

Dell recommends installing Emulex

using a DRAC II

 

33 MHz.

 

or plan to use one

 

 

cLAN adapters in PCI slot 3, 4, or 5.

 

Bus 2: PCI slots 3,

 

in the future,

 

 

 

 

 

 

install the DRAC

 

4, and 5 are 64 bit,

 

 

 

 

 

II in PCI slot 7.

 

33 MHz.

 

 

 

 

 

 

 

Bus 3: PCI slots 1

 

 

 

 

and 2 are 64 bit,

 

 

 

 

66 MHz.

 

 

 

 

 

 

 

 

2550

Bus 1: PCI slots 1,

Install in any available

NOTE: The Broadcom NIC drivers in

PCI slot 2 is

 

2, and 3 are 64 bit,

PCI slot.

your cluster node must be one of the

dedicated to

 

33 MHz.

If you are not currently

following versions:

interface with the

 

 

Windows 2000 Advanced

optional DRAC II.

 

 

using a DRAC II and do

 

 

not plan to use one in the

Server—version 2.43 or later

 

 

 

future, Dell recommends

Windows NT Server 4.0,

 

 

 

that you install one RAID

Enterprise Edition—version 2.46

 

 

 

controller in the 32-bit

or later

 

 

 

slot, even if the RAID

The Broadcom NIC firmware

 

 

 

controller is a 64-bit

version must be 1.12 or later. The

 

 

 

controller.

integrated Broadcom NIC

 

 

 

 

firmware revisions were created in

 

 

 

 

ascending order, starting with

 

 

 

 

version 1.1 and ending with 1.12

 

 

 

 

or later. Consequently, version 1.2

 

 

 

 

is an earlier version than version

 

 

 

 

1.12. To upgrade the firmware, at

 

 

 

 

the prompt, type upgf x boot y

 

 

 

 

where x is the device number of

 

 

 

 

the integrated Broadcom NIC and

 

 

 

 

y is the drive letter of where the

 

 

 

 

firmware file is located. The utility

 

 

 

 

upgrades the integrated NIC

 

 

 

 

firmware in your system. The driver

 

 

 

 

and utility to upgrade the firmware

 

 

 

 

are available on the Dell Support

 

 

 

 

website at support.dell.com.

 

Platform Guide

1-5

Page 7
Image 7
Dell SL400, SE400 manual PowerEdge, PCI Buses, RAID Controller, NICs, DRAC II or, System, website at support.dell.com