DeLonghi DE302IB manual Do not install the appliance near inflammable materials eg. curtains

Models: DE302IB

1 24
Download 24 pages 11.98 Kb
Page 19
Image 19
Fig. 4.2

This cooktop can be built into a working surface 30 to 40 mm thick and 600 mm deep.

In order to install the ceramic hob into the kitchen fixture, a hole with the dimensions shown in figure 4.1 has to be made, keeping in consideration the following:

The cooktop shall not be installed directly above a dishwasher, fridge, freezer, washing machine or clothes dryer, as the humidity may damage the cooktop electronics.

If the cooktop is installed above an oven, the oven shall be provided with cooling fan. The two appliances should be connected to the electrical supply with independent connections.

IMPORTANT WARNING! This cooktop requires adequate supply of fresh, cool air to fully function. The base of the cooktop must have direct unrestricted ventilation to the room where the cooktop is installed. Follow the requirements of figure 4.3.

The ceramic hob must be kept no less than 60 mm away from any side wall.

450 mm

650 mm

60 mm minimum between the side of the cut-out and the side wall

Fig. 4.2

The rear wall must be at least 50 mm from the ceramic hob.

There must be a distance of at least 650 mm between the hob and any wall cupboard or extractor hood positioned immediately above (see fig. 4.2).

The coatings of the walls of the unit or appliances near the cooktop must be heat resistant.

Do not install the appliance near inflammable materials (eg. curtains).

 

7 mm

7 mm

Oven with

70 mm

 

 

 

cooling fan

 

 

min 30 mm

 

min 30 mm

Minimum clearances and

 

Minimum clearances and

ventilation requirements

Fig. 4.3

ventilation requirements

(oven installed below)

(cupboard or drawer space below)

 

 

19