DeLonghi DE302IB manual Installation

Models: DE302IB

1 24
Download 24 pages 11.98 Kb
Page 18
Image 18
4 INSTALLATION

4 INSTALLATION

CAUTION:

This appliance shall only be serviced by authorized personnel.

This appliance is to be installed only by an authorised person according to the cur- rent local regulations and in observation of the manufacturer’s instructions.

Incorrect installation, for which the manufacturer accepts no responsibility, may cause personal injury of damage.

Always disconnect the cooktop from mains power supply before carrying out any maintenance operations or repairs.

WARNING !

We would point out that the adhesive which bonds the plastic laminate to the furniture must withstand temperatures not less than 150 °C to avoid delamination.

The appliance must be housed in heat resistant units.

The walls of the units must be capable of resisting temperatures of 75 °C above room temperature.

0 51

A

27

5

 

Fig. 4.1

Fig. 4.1 300

50

(1)

 

490

 

50 mm

from the top of

 

countertop to bottom

 

 

metal cover

A

 

 

68 mm

from the top of

 

 

countertop to

 

 

terminal block

 

 

 

(1): at least 50 mm between the back side of the cut-out and the back of the countertop.