| SERVICE | ! | WARNING |
| PROCEDURES | ||
| Never service heater while it is plugged in, operating, or | ||
|
| hot. Severe burns and electrical shock can occur. | |
|
| Upper | Upper |
Upper Shell Removal | Shell | Shell | |
|
| ||
1. | Remove screws along each | Fan | |
| side of heater using 5/16" | Guard | |
|
|
| |
| attach upper and lower |
|
|
| shells together. |
|
|
2. | Lift upper shell off. |
| Fan |
3. | Remove fan guard. |
| Guard |
Figure 9 - Upper Shell Removal, | Figure | 10 - Upper Shell Removal, |
30/70,000 BTU/Hr Models | 90,000 | BTU/Hr Model |
Upper
Shell
Fan Guard
150 SHELL REMOVAL EA/EB Euro | PV 020 |
Figure 11 - Upper Shell Removal, 150,000 BTU/Hr Model
Fuel Filter | Fuel Filter | |
(30/70,000 BTU/Hr Models) | ||
|
1.Remove side cover screws using 5/16"
2.Remove side cover.
3.Pull rubber fuel line off fuel filter neck.
4.Carefully pry bushing and fuel filter out of fuel tank.
5.Wash fuel filter with clean
| fuel and replace in tank. |
|
|
|
| |
|
|
|
|
| ||
| Side Cover | |||||
6. | Attach rubber fuel line to | |||||
|
|
| Fuel Line | |||
| fuel filter neck. |
|
|
| ||
|
|
|
|
| ||
7. | Replace side cover. |
|
|
|
| |
|
| Figure 12 - Fuel Filter Removal, 30/70,000 BTU/Hr Models | ||||
10 |
| |||||
| ||||||
|
|
|
|
| ||
|
|
|
|
|
|
100743